ControlKraft Touch
Touchscreen control system specially designed
for industrial applications.
ControlKraft Touch
Touchscreen control system specially designed
for industrial applications.
Say Goodbye to Separate Control Systems.

The ControlKraft Touch is a state-of-the-art touchscreen control system designed to operate in harsh environments for industrial applications. The controller’s modern design eliminates the need – and unnecessary cost — of multiple control units as it allows the end user to independently control up to 10 FlexKraft™ units or up to 20 different outputs from one control screen.
Available in four sizes, ControlKraft Touch monitors and displays real time operating parameters, as well as the ability to view process data over a defined time period. The system is enclosed in a sealed case specially designed to withstand harsh, corrosive environments commonly encountered with industrial applications.
Available Sizes |
FlexKraft™ Control Capability |
Touch 7″ |
1-3 rectifiers in single mode, up to 6 outputs in dual mode |
Touch 10″ |
1-8 rectifiers in single mode, up to 16 outputs in dual mode |
Touch 12″ |
1-10 rectifiers in single mode, up to 20 outputs in dual mode |
Touch 15″ |
1-10 rectifiers in single mode, up to 20 outputs in dual mode |
- Simultaneous control of 1 to 10 rectifiers, depending on type/size of the control panel
- Each rectifier can be controlled individually in Single or Dual mode.
- Set the rectifier set values in DC mode or different plating recipes in program mode
- Work with profiles of the rectifier settings (create, edit, apply, delete, import and export from flash drive)
- Monitoring and displaying all main parameters of FlexKraft rectifier (in real time and over a certain period of time)
- Output current
- Output voltage
- Ampere-hours
- Process timer
- Status and operating mode of a rectifier
- Notifying an operator of malfunctions (2 critical levels)
- Logging failures and events
- Upload of failures and events archive to USB drive.
- Working with step-by-step programs of a rectifier (Loading, uploading, selecting and launching)
- Creating programs on the ControlKraft Touch and starting them on a rectifier
- Saving the created programs to the integrated flash memory of ControlKraft Touch and exporting/importing them to USB drive. It is possible to save up to 100 programs for each rectifier.
- Independent launch of programs for each side of a rectifier in “Dual” mode
- Communicating with rectifiers via Modbus RTU protocol
- Set of tools for work with these programs/configurations or data archives on computer/laptop (OPTIONAL)
Display |
7″ TFT |
10.4″ TFT |
12.1″ TFT |
15″ TFT |
Resolution |
800×480 |
800×600 |
1024×768 |
1024×768 |
Aspect Ratio |
16:9 |
4:3 |
4:3 |
4:3 |
Brightness (cd/m2) |
500 |
400 |
500 |
350 |
Contrast Ratio |
500:1 |
400:1 |
700:1 |
700:1 |
Backlight Type |
LED |
LED |
LED |
LED |
Backlight Life Time |
30,000 hr. |
30,000 hr. |
50,000 hr. |
50,000 hr. |
Protection |
IP66 front Panel (O ring seal) |
IP65 front Panel (O ring seal) |
IP66 front Panel (O ring seal) |
IP65 front Panel (O ring seal) |
Operating Temperature |
32-120°F |
32-120°F |
32-120°F |
32-120°F |
SD Card Slot |
Yes |
Yes |
Yes |
Yes |
USB |
USB 2.0 x 1 |
USB 2.0 x 1 |
USB 2.0 x 1 |
USB 2.0 x 1 |
Specifications are subject to change without notice.
- Remote control box ’basic version’ with analogue or digital display, potentiometers etc.
- RS-232C interface for control of one power supply.
- Analogue/Digital interface. Two controls, and two status signals 0–10 VDC and two controls and two status signals 24 VDC.
- Standard configuration: Iset, Uset, lact and Uact: 0–10 VDC. On/Off, Block/Run, Power On and Alarm as digital signals: 24 VDC.
- Analogue interface with four inputs and four outputs galvanically isolated. Control and status signals 0-10 VDC or 0/4–20 mA.
- Standard configuration: Iset, Uset, lact and Uact: 4–20 mA
- Digital interface with four inputs and four outputs. Control signals 24 VDC. Status signals via voltage free relay contacts; contact data 24 VDC or 24 VAC. Standard configuration: On/Off, Block/Run, Power On and Alarm.
- Raise / Lower function.
- Electrically controlled AC breaker.
- External reference shunt, 60 mV.
- Polarity Reversal.